§ 25-116. Formula for computing payments.  


Latest version.
  • ICR = Qf / Qd × QU + BODf / BODd + BOD u × SSf / SSd × SS u + Nf / Nd × N u × ;frac;P

    Where:

    ICR = Cost to be recovered from an industrial user ($/billing period).
    Qf = The sum of the federal grant costs allocable to flow capacity ($).
    Qd = The design flow capacity of the treatment works (gallons/day).
    Qu = The average quarterly waste water flow contributed by the user during the billing period (gallons/day).
    BOD f = The sum of the federal grant costs allocable to BOD 5 capacity ($).
    BOD d = The design BOD 5 capacity of the treatment works (pounds/day).
    BOD u = The average daily poundage of five-day biochemical oxygen demand twenty (20) degrees contributed by the user during the billing period (pounds/day).
    SS f = The sum of the federal grant cost allocable to suspended solids capacity ($).
    SS d = The design suspended solids capacity of the treatment works (pounds/day).
    SS u = The average daily poundage of suspended solids contributed by the user during the billing period (pounds/day).
    N f = The sum of the federal grant costs allocable to nitrogen capacity ($).
    N d = The design nitrogen capacity of the treatment works (pounds/day).
    N u = The average daily poundage of nitrogen as N contributed by the user during the billing period (pounds/day).
    P = Length of the billing period (days).
    R = Length of the cost recovery period (days).

     

    (Ord. No. 80-1700-151, 3-4-80)